このページの翻訳:
- 日本語 (ja)
- English (en)
最近の更新
Tag Cloud
このページへのアクセス
今日: 7 / 昨日: 0
総計: 892
- Dokuwiki.fl8.jp(272)
- 13 CentOS6メール設定(15)
- 34 UnboundでHA構成(14)
- 05 rsync(14)
- FreeBSD カーネル再構築(13)
最近の更新
このページへのアクセス
今日: 7 / 昨日: 0
総計: 892
[root@localhost MegaCli]# ./MegaCli64 -PDList -aALL Adapter #0 Enclosure Device ID: N/A Slot Number: 0 Device Id: 0 Sequence Number: 0 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 931.512 GB [0x74706db0 Sectors] Non Coerced Size: 931.012 GB [0x74606db0 Sectors] Coerced Size: 930.390 GB [0x744c8000 Sectors] Firmware state: Online Connected Port Number: 0 Inquiry Data: STF604MRHitachi HDT72101ST6O FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Foreign State: None Device Speed: 3.0Gb/s Link Speed: 3.0Gb/s Media Type: Hard Disk Device Enclosure Device ID: N/A Slot Number: 2 Device Id: 2 Sequence Number: 1 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 931.512 GB [0x74706db0 Sectors] Non Coerced Size: 931.012 GB [0x74606db0 Sectors] Coerced Size: 930.390 GB [0x744c8000 Sectors] Firmware state: Rebuild Connected Port Number: 2 Inquiry Data: JP9960HZHitachi HDS72101JP4O FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Foreign State: None Device Speed: 3.0Gb/s Link Speed: 3.0Gb/s Media Type: Hard Disk Device Exit Code: 0x00
PhyDrvの箇所で、Enclosure IDを何も入れなくて良いみたい。
[root@localhost MegaCli]# ./MegaCli64 -PDRbld -ShowProg -PhysDrv[:2] -a0 Rebuild Progress on Device at Enclosure N/A, Slot 2 Completed 3% in 561 Minutes.
# /opt/MegaRAID/MegaCli/MegaCli64 -LDInfo -Lall -aALL Adapter 0 -- Virtual Drive Information: Virtual Drive: 0 (Target Id: 0) Name : RAID Level : Primary-5, Secondary-0, RAID Level Qualifier-3 Size : 450.0 GB Sector Size : 512 Parity Size : 150.0 GB State : Optimal Strip Size : 64 KB Number Of Drives : 4 Span Depth : 1 Default Cache Policy: WriteThrough, ReadAhead, Cached, No Write Cache if Bad BBU Current Cache Policy: WriteThrough, ReadAhead, Cached, No Write Cache if Bad BBU Default Access Policy: Read/Write Current Access Policy: Read/Write Disk Cache Policy : Enabled Encryption Type : None Default Power Savings Policy: Controller Defined Current Power Savings Policy: None Can spin up in 1 minute: Yes LD has drives that support T10 power conditions: Yes LD's IO profile supports MAX power savings with cached writes: No Bad Blocks Exist: No Is VD Cached: Yes Cache Cade Type : Read Only Virtual Drive: 1 (Target Id: 1) Name : RAID Level : Primary-5, Secondary-0, RAID Level Qualifier-3 Size : 5.014 TB Sector Size : 512 Parity Size : 1.670 TB State : Optimal Strip Size : 64 KB Number Of Drives : 4 Span Depth : 1 Default Cache Policy: WriteThrough, ReadAhead, Cached, No Write Cache if Bad BBU Current Cache Policy: WriteThrough, ReadAhead, Cached, No Write Cache if Bad BBU Default Access Policy: Read/Write Current Access Policy: Read/Write Disk Cache Policy : Enabled Encryption Type : None Default Power Savings Policy: Controller Defined Current Power Savings Policy: None Can spin up in 1 minute: Yes LD has drives that support T10 power conditions: Yes LD's IO profile supports MAX power savings with cached writes: No Bad Blocks Exist: No Is VD Cached: Yes Cache Cade Type : Read Only Exit Code: 0x00