# hpssacli ctrl all show Smart HBA H240 in Slot 2 (RAID Mode) (sn: PDNNK0BRH9O0OE)
# hpssacli ctrl slot=0 modify nobatterywritecache=enable
# hpssacli ctrl slot=0 modify drivewritecache=enable
# hpssacli ctrl slot=0 modify cacheratio=10/90
hpssacli Posted on December 6, 2018 by Alwin Show configuration: /opt/hp/hpssacli/bin/hpssacli ctrl all show config Controller status /opt/hp/hpssacli/bin/hpssacli ctrl all show status Show detailed controller information for all controllers /opt/hp/hpssacli/bin/hpssacli ctrl all show detail Show detailed controller information for controller in slot 0 /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 show detail Rescan for New Devices /opt/hp/hpssacli/bin/hpssacli rescan Physical disk status /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd all show status Show detailed physical disk information /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd all show detail Logical disk status /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld all show status View Detailed Logical Drive Status /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 show Create New RAID 0 Logical Drive /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:2 raid=0 Create New RAID 1 Logical Drive /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2 raid=1 Create New RAID 5 Logical Drive /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2,2I:1:6,2I:1:7,2I:1:8 raid=5 Delete Logical Drive /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 delete Add New Physical Drive to Logical Volume /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 add drives=2I:1:6,2I:1:7 Add Spare Disks /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 array all add spares=2I:1:6,2I:1:7 Enable Drive Write Cache /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify dwc=enable Disable Drive Write Cache /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify dwc=disable Erase Physical Drive /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd 2I:1:6 modify erase Turn on Blink Physical Disk LED /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 modify led=on Turn off Blink Physical Disk LED /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 modify led=off Modify smart array cache read and write ratio (cacheratio=readratio/writeratio) /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify cacheratio=100/0 Enable smart array write cache when no battery is present (No-Battery Write Cache option) /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify nbwc=enable Disable smart array cache for certain Logical Volume /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=disable Enable smart array cache for certain Logical Volume /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=enable Enable SSD Smart Path /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 array a modify ssdsmartpath=enable Disable SSD Smart Path /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 array a modify ssdsmartpath=disable
hpssacli ctrl slot=0 physicaldrive 1I:1:2 modify disablepd
再確認
hpssacli ctrl slot=0 show config Smart Array P420i in Slot 0 (Embedded) (sn: 0014380282E0CB0) Port Name: 1I Port Name: 2I Internal Drive Cage at Port 1I, Box 1, OK Internal Drive Cage at Port 2I, Box 0, OK array A (SAS, Unused Space: 0 MB) logicaldrive 1 (136.7 GB, RAID 1, Interim Recovery Mode) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, Failed) SEP (Vendor ID PMCSIERA, Model SRCv8x6G) 380 (WWID: 50014380282E0CBF)