hpssacli(hpacucli)でPDをdisabledにしてあげると、障害テストできる。
PDが正常であれば再起動、もしくはディスク抜き差しでRebuildが走ります。
# hpssacli ctrl slot=0 show config Smart Array P420i in Slot 0 (Embedded) (sn: 0014380282E0CB0) Port Name: 1I Port Name: 2I Internal Drive Cage at Port 1I, Box 1, OK Internal Drive Cage at Port 2I, Box 0, OK array A (SAS, Unused Space: 0 MB) logicaldrive 1 (136.7 GB, RAID 1, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, OK) SEP (Vendor ID PMCSIERA, Model SRCv8x6G) 380 (WWID: 50014380282E0CBF)
# hpssacli ctrl slot=0 physicaldrive 1I:1:2 modify disablepd
# hpssacli ctrl slot=0 show config Smart Array P420i in Slot 0 (Embedded) (sn: 0014380282E0CB0) Port Name: 1I Port Name: 2I Internal Drive Cage at Port 1I, Box 1, OK Internal Drive Cage at Port 2I, Box 0, OK array A (SAS, Unused Space: 0 MB) logicaldrive 1 (136.7 GB, RAID 1, Interim Recovery Mode) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, Failed) SEP (Vendor ID PMCSIERA, Model SRCv8x6G) 380 (WWID: 50014380282E0CBF)