このページの翻訳:
- 日本語 (ja)
- English (en)
最近の更新
Tag Cloud
このページへのアクセス
今日: 3 / 昨日: 0
総計: 888
- Dokuwiki.fl8.jp(179)
- 13 CentOS6メール設定(10)
- 02 ProFTPD(9)
- 14 rsync(9)
最近の更新
このページへのアクセス
今日: 3 / 昨日: 0
総計: 888
[root@localhost MegaCli]# ./MegaCli64 -PDList -aALL
Adapter #0
Enclosure Device ID: N/A
Slot Number: 0
Device Id: 0
Sequence Number: 0
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SATA
Raw Size: 931.512 GB [0x74706db0 Sectors]
Non Coerced Size: 931.012 GB [0x74606db0 Sectors]
Coerced Size: 930.390 GB [0x744c8000 Sectors]
Firmware state: Online
Connected Port Number: 0
Inquiry Data: STF604MRHitachi HDT72101ST6O
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Foreign State: None
Device Speed: 3.0Gb/s
Link Speed: 3.0Gb/s
Media Type: Hard Disk Device
Enclosure Device ID: N/A
Slot Number: 2
Device Id: 2
Sequence Number: 1
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SATA
Raw Size: 931.512 GB [0x74706db0 Sectors]
Non Coerced Size: 931.012 GB [0x74606db0 Sectors]
Coerced Size: 930.390 GB [0x744c8000 Sectors]
Firmware state: Rebuild
Connected Port Number: 2
Inquiry Data: JP9960HZHitachi HDS72101JP4O
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Foreign State: None
Device Speed: 3.0Gb/s
Link Speed: 3.0Gb/s
Media Type: Hard Disk Device
Exit Code: 0x00
PhyDrvの箇所で、Enclosure IDを何も入れなくて良いみたい。
[root@localhost MegaCli]# ./MegaCli64 -PDRbld -ShowProg -PhysDrv[:2] -a0 Rebuild Progress on Device at Enclosure N/A, Slot 2 Completed 3% in 561 Minutes.
# /opt/MegaRAID/MegaCli/MegaCli64 -LDInfo -Lall -aALL
Adapter 0 -- Virtual Drive Information:
Virtual Drive: 0 (Target Id: 0)
Name :
RAID Level : Primary-5, Secondary-0, RAID Level Qualifier-3
Size : 450.0 GB
Sector Size : 512
Parity Size : 150.0 GB
State : Optimal
Strip Size : 64 KB
Number Of Drives : 4
Span Depth : 1
Default Cache Policy: WriteThrough, ReadAhead, Cached, No Write Cache if Bad BBU
Current Cache Policy: WriteThrough, ReadAhead, Cached, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy : Enabled
Encryption Type : None
Default Power Savings Policy: Controller Defined
Current Power Savings Policy: None
Can spin up in 1 minute: Yes
LD has drives that support T10 power conditions: Yes
LD's IO profile supports MAX power savings with cached writes: No
Bad Blocks Exist: No
Is VD Cached: Yes
Cache Cade Type : Read Only
Virtual Drive: 1 (Target Id: 1)
Name :
RAID Level : Primary-5, Secondary-0, RAID Level Qualifier-3
Size : 5.014 TB
Sector Size : 512
Parity Size : 1.670 TB
State : Optimal
Strip Size : 64 KB
Number Of Drives : 4
Span Depth : 1
Default Cache Policy: WriteThrough, ReadAhead, Cached, No Write Cache if Bad BBU
Current Cache Policy: WriteThrough, ReadAhead, Cached, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy : Enabled
Encryption Type : None
Default Power Savings Policy: Controller Defined
Current Power Savings Policy: None
Can spin up in 1 minute: Yes
LD has drives that support T10 power conditions: Yes
LD's IO profile supports MAX power savings with cached writes: No
Bad Blocks Exist: No
Is VD Cached: Yes
Cache Cade Type : Read Only
Exit Code: 0x00