このページの2つのバージョン間の差分を表示します。
01_linux:99_その他:37_megacli_smart [2018/12/11 04:13] – 作成 matsui | 01_linux:99_その他:37_megacli_smart [2018/12/11 04:18] (現在) – matsui | ||
---|---|---|---|
行 1: | 行 1: | ||
====== 37 MegaCliのSmart情報 ====== | ====== 37 MegaCliのSmart情報 ====== | ||
+ | ===== MegaCliでDevice ID確認 ===== | ||
- | {{tag> | + | < |
+ | # / | ||
+ | |||
+ | Adapter #0 | ||
+ | |||
+ | Enclosure Device ID: 64 | ||
+ | Slot Number: 0 | ||
+ | Drive' | ||
+ | Enclosure position: N/A | ||
+ | Device Id: 2 | ||
+ | WWN: 5000c5007b397b66 | ||
+ | Sequence Number: 2 | ||
+ | Media Error Count: 0 | ||
+ | Other Error Count: 0 | ||
+ | Predictive Failure Count: 0 | ||
+ | Last Predictive Failure Event Seq Number: 0 | ||
+ | PD Type: SATA | ||
+ | |||
+ | Raw Size: 465.761 GB [0x3a386030 Sectors] | ||
+ | Non Coerced Size: 465.261 GB [0x3a286030 Sectors] | ||
+ | Coerced Size: 464.729 GB [0x3a175800 Sectors] | ||
+ | Sector Size: 0 | ||
+ | Logical Sector Size: 0 | ||
+ | Physical Sector Size: 0 | ||
+ | Firmware state: Online, Spun Up | ||
+ | Commissioned Spare : No | ||
+ | Emergency Spare : No | ||
+ | Device Firmware Level: CC03 | ||
+ | Shield Counter: 0 | ||
+ | Successful diagnostics completion on : N/A | ||
+ | SAS Address(0): 0x4433221100000000 | ||
+ | Connected Port Number: 0(path0) | ||
+ | Inquiry Data: | ||
+ | FDE Capable: Not Capable | ||
+ | FDE Enable: Disable | ||
+ | Secured: Unsecured | ||
+ | Locked: Unlocked | ||
+ | Needs EKM Attention: No | ||
+ | Foreign State: None | ||
+ | Device Speed: 6.0Gb/s | ||
+ | Link Speed: 6.0Gb/s | ||
+ | Media Type: Hard Disk Device | ||
+ | Drive: | ||
+ | Drive Temperature :26C (78.80 F) | ||
+ | PI Eligibility: | ||
+ | Drive is formatted for PI information: | ||
+ | PI: No PI | ||
+ | Port-0 : | ||
+ | Port status: Active | ||
+ | Port's Linkspeed: 6.0Gb/s | ||
+ | Drive has flagged a S.M.A.R.T alert : No | ||
+ | |||
+ | |||
+ | |||
+ | Enclosure Device ID: 64 | ||
+ | Slot Number: 1 | ||
+ | Drive' | ||
+ | Enclosure position: N/A | ||
+ | Device Id: 3 | ||
+ | WWN: 5000c5007b39948b | ||
+ | Sequence Number: 2 | ||
+ | Media Error Count: 0 | ||
+ | Other Error Count: 0 | ||
+ | Predictive Failure Count: 0 | ||
+ | Last Predictive Failure Event Seq Number: 0 | ||
+ | PD Type: SATA | ||
+ | |||
+ | Raw Size: 465.761 GB [0x3a386030 Sectors] | ||
+ | Non Coerced Size: 465.261 GB [0x3a286030 Sectors] | ||
+ | Coerced Size: 464.729 GB [0x3a175800 Sectors] | ||
+ | Sector Size: 0 | ||
+ | Logical Sector Size: 0 | ||
+ | Physical Sector Size: 0 | ||
+ | Firmware state: Online, Spun Up | ||
+ | Commissioned Spare : No | ||
+ | Emergency Spare : No | ||
+ | Device Firmware Level: CC03 | ||
+ | Shield Counter: 0 | ||
+ | Successful diagnostics completion on : N/A | ||
+ | SAS Address(0): 0x4433221101000000 | ||
+ | Connected Port Number: 1(path0) | ||
+ | Inquiry Data: | ||
+ | FDE Capable: Not Capable | ||
+ | FDE Enable: Disable | ||
+ | Secured: Unsecured | ||
+ | Locked: Unlocked | ||
+ | Needs EKM Attention: No | ||
+ | Foreign State: None | ||
+ | Device Speed: 6.0Gb/s | ||
+ | Link Speed: 6.0Gb/s | ||
+ | Media Type: Hard Disk Device | ||
+ | Drive: | ||
+ | Drive Temperature :27C (80.60 F) | ||
+ | PI Eligibility: | ||
+ | Drive is formatted for PI information: | ||
+ | PI: No PI | ||
+ | Port-0 : | ||
+ | Port status: Active | ||
+ | Port's Linkspeed: 6.0Gb/s | ||
+ | Drive has flagged a S.M.A.R.T alert : No | ||
+ | |||
+ | |||
+ | |||
+ | |||
+ | Exit Code: 0x00 | ||
+ | </ | ||
+ | |||
+ | ===== smartctlで情報取得 ===== | ||
+ | |||
+ | | ||
+ | |||
+ | Device ID: 2のSmart情報を取得する場合は下記 | ||
+ | < | ||
+ | # smartctl -a -d sat+megaraid, | ||
+ | smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.10.0+2] (local build) | ||
+ | Copyright (C) 2002-11 by Bruce Allen, http:// | ||
+ | |||
+ | === START OF INFORMATION SECTION === | ||
+ | Device Model: | ||
+ | Serial Number: | ||
+ | LU WWN Device Id: 5 000c50 07b397b66 | ||
+ | Firmware Version: CC03 | ||
+ | User Capacity: | ||
+ | Sector Size: 512 bytes logical/ | ||
+ | Device is: Not in smartctl database [for details use: -P showall] | ||
+ | ATA Version is: 8 | ||
+ | ATA Standard is: ATA-8-ACS revision 4 | ||
+ | Local Time is: Tue Dec 11 13:16:37 2018 JST | ||
+ | SMART support is: Available - device has SMART capability. | ||
+ | SMART support is: Enabled | ||
+ | |||
+ | === START OF READ SMART DATA SECTION === | ||
+ | SMART overall-health self-assessment test result: PASSED | ||
+ | Warning: This result is based on an Attribute check. | ||
+ | |||
+ | General SMART Values: | ||
+ | Offline data collection status: | ||
+ | was completed without error. | ||
+ | Auto Offline Data Collection: Enabled. | ||
+ | Self-test execution status: | ||
+ | without error or no self-test has ever | ||
+ | been run. | ||
+ | Total time to complete Offline | ||
+ | data collection: ( 625) seconds. | ||
+ | Offline data collection | ||
+ | capabilities: | ||
+ | Auto Offline data collection on/off support. | ||
+ | Suspend Offline collection upon new | ||
+ | command. | ||
+ | Offline surface scan supported. | ||
+ | Self-test supported. | ||
+ | Conveyance Self-test supported. | ||
+ | Selective Self-test supported. | ||
+ | SMART capabilities: | ||
+ | power-saving mode. | ||
+ | Supports SMART auto save timer. | ||
+ | Error logging capability: | ||
+ | General Purpose Logging supported. | ||
+ | Short self-test routine | ||
+ | recommended polling time: ( 1) minutes. | ||
+ | Extended self-test routine | ||
+ | recommended polling time: ( 96) minutes. | ||
+ | Conveyance self-test routine | ||
+ | recommended polling time: ( 2) minutes. | ||
+ | SCT capabilities: | ||
+ | SCT Error Recovery Control supported. | ||
+ | SCT Feature Control supported. | ||
+ | SCT Data Table supported. | ||
+ | |||
+ | SMART Attributes Data Structure revision number: 10 | ||
+ | Vendor Specific SMART Attributes with Thresholds: | ||
+ | ID# ATTRIBUTE_NAME | ||
+ | 1 Raw_Read_Error_Rate | ||
+ | 3 Spin_Up_Time | ||
+ | 4 Start_Stop_Count | ||
+ | 5 Reallocated_Sector_Ct | ||
+ | 7 Seek_Error_Rate | ||
+ | 9 Power_On_Hours | ||
+ | 10 Spin_Retry_Count | ||
+ | 12 Power_Cycle_Count | ||
+ | 184 End-to-End_Error | ||
+ | 187 Reported_Uncorrect | ||
+ | 188 Command_Timeout | ||
+ | 189 High_Fly_Writes | ||
+ | 190 Airflow_Temperature_Cel 0x0022 | ||
+ | 191 G-Sense_Error_Rate | ||
+ | 192 Power-Off_Retract_Count 0x0032 | ||
+ | 193 Load_Cycle_Count | ||
+ | 194 Temperature_Celsius | ||
+ | 195 Hardware_ECC_Recovered | ||
+ | 197 Current_Pending_Sector | ||
+ | 198 Offline_Uncorrectable | ||
+ | 199 UDMA_CRC_Error_Count | ||
+ | |||
+ | SMART Error Log Version: 1 | ||
+ | No Errors Logged | ||
+ | |||
+ | SMART Self-test log structure revision number 1 | ||
+ | No self-tests have been logged. | ||
+ | |||
+ | |||
+ | SMART Selective self-test log data structure revision number 1 | ||
+ | | ||
+ | 1 0 0 Not_testing | ||
+ | 2 0 0 Not_testing | ||
+ | 3 0 0 Not_testing | ||
+ | 4 0 0 Not_testing | ||
+ | 5 0 0 Not_testing | ||
+ | Selective self-test flags (0x0): | ||
+ | After scanning selected spans, do NOT read-scan remainder of disk. | ||
+ | If Selective self-test is pending on power-up, resume after 0 minute delay. | ||
+ | </ | ||
+ | |||
+ | {{tag> |