# hpssacli ctrl all show Smart HBA H240 in Slot 2 (RAID Mode) (sn: PDNNK0BRH9O0OE)
# hpssacli ctrl slot=0 modify nobatterywritecache=enable
# hpssacli ctrl slot=0 modify drivewritecache=enable
# hpssacli ctrl slot=0 modify cacheratio=10/90
hpssacli Posted on December 6, 2018 by Alwin Show configuration: /opt/hp/hpssacli/bin/hpssacli ctrl all show config Controller status /opt/hp/hpssacli/bin/hpssacli ctrl all show status Show detailed controller information for all controllers /opt/hp/hpssacli/bin/hpssacli ctrl all show detail Show detailed controller information for controller in slot 0 /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 show detail Rescan for New Devices /opt/hp/hpssacli/bin/hpssacli rescan Physical disk status /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd all show status Show detailed physical disk information /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd all show detail Logical disk status /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld all show status View Detailed Logical Drive Status /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 show Create New RAID 0 Logical Drive /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:2 raid=0 Create New RAID 1 Logical Drive /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2 raid=1 Create New RAID 5 Logical Drive /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2,2I:1:6,2I:1:7,2I:1:8 raid=5 Delete Logical Drive /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 delete Add New Physical Drive to Logical Volume /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 add drives=2I:1:6,2I:1:7 Add Spare Disks /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 array all add spares=2I:1:6,2I:1:7 Enable Drive Write Cache /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify dwc=enable Disable Drive Write Cache /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify dwc=disable Erase Physical Drive /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd 2I:1:6 modify erase Turn on Blink Physical Disk LED /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 modify led=on Turn off Blink Physical Disk LED /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 modify led=off Modify smart array cache read and write ratio (cacheratio=readratio/writeratio) /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify cacheratio=100/0 Enable smart array write cache when no battery is present (No-Battery Write Cache option) /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify nbwc=enable Disable smart array cache for certain Logical Volume /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=disable Enable smart array cache for certain Logical Volume /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=enable Enable SSD Smart Path /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 array a modify ssdsmartpath=enable Disable SSD Smart Path /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 array a modify ssdsmartpath=disable