ユーザ用ツール

サイト用ツール


サイドバー

このページの翻訳:



最近の更新



Tag Cloud

01_linux:99_その他:60_adaptech_raidのledランプを付ける

60 adaptech_raidのledランプを付ける.

arcconfigコマンド

ARCCONF IDENTIFY <Controller#> LOGICALDRIVE <LogicalDrive#>
ARCCONF IDENTIFY <Controller#> DEVICE <Channel#> <ID>

http://docs.oracle.com/cd/E19045-01/blade.x6240/820-2145-12/chapter2.html#0_78057

Example 1

   --------------------------------------------------------
   Logical device segment information
   --------------------------------------------------------
   Segment 0                                : Present (0,10) 9WK2YZ770000C1244YVH
   Segment 1                                : Present (0,11) 9WK2YZRV00009121WR4P
      Device #3
         Device is a Hard drive
         State                              : Online
         Supported                          : Yes
         Transfer Speed                     : SAS 3.0 Gb/s
         Reported Channel,Device(T:L)       : 0,10(10:0)
         Reported Location                  : Enclosure 0, Slot 2
         Reported ESD(T:L)                  : 2,0(0:0)
         Vendor                             : SEAGATE
         Model                              : ST31000424SS
         Firmware                           : 0006
         Serial number                      : 9WK2YZ770000C1244YVH

この9WK2YZ770000C1244YVHにランプを付けたい場合は

# arcconf identify 1 device 0 10
Controllers found: 1
The specified device is blinking.
Press any key to stop the blinking.

エンターを押すと点灯を終了する。

Example 2

   --------------------------------------------------------
   Logical device segment information
   --------------------------------------------------------
   Segment 0                                : Present (Controller:1,Enclosure:0,Slot:2) 9WK2YZ770000C1244YVH
   Segment 1                                : Present (Controller:1,Enclosure:0,Slot:3) 9WK2YZRV00009121WR4P
   Segment 2                                : Present (Controller:1,Enclosure:0,Slot:4) 9WK2Z3PM0000C123BL22
   Segment 3                                : Present (Controller:1,Enclosure:0,Slot:5) 9WK2K3QF00009118TBEL
   Segment 4                                : Present (Controller:1,Enclosure:0,Slot:6) 9WK2YZDG0000C123E0DL
   Segment 5                                : Present (Controller:1,Enclosure:0,Slot:7) 9WK2LH5X00009119Z0GH
   Segment 6                                : Present (Controller:1,Enclosure:0,Slot:8) 9WK4ZCWF0000C150027E
   Segment 7                                : Present (Controller:1,Enclosure:0,Slot:9) 9WK2LFMD00009120N08H
   Segment 8                                : Present (Controller:1,Enclosure:0,Slot:10) 9WK18DDB0000C1044GAM
   Segment 9                                : Missing
   Segment 10                               : Present (Controller:1,Enclosure:0,Slot:12) 9WK2YZV900009120RJBJ
   Segment 11                               : Present (Controller:1,Enclosure:0,Slot:13) 9WK2LH9C00009120N8VJ
   Segment 12                               : Present (Controller:1,Enclosure:0,Slot:14) 9WK36B8D00009217FT3J
   Segment 13                               : Present (Controller:1,Enclosure:0,Slot:15) 9WK2LG0H00009119MBCG
   
      Device #11
         Device is a Hard drive
         State                              : Online
         Supported                          : Yes
         Transfer Speed                     : SAS 3.0 Gb/s
         Reported Channel,Device(T:L)       : 0,18(18:0)
         Reported Location                  : Enclosure 0, Slot 10
         Reported ESD(T:L)                  : 2,0(0:0)
         Vendor                             : SEAGATE
         Model                              : ST31000424SS
         Firmware                           : 0005
         Serial number                      : 9WK18DDB0000C1044GAM
         World-wide name                    : 5000C50021293218
         Size                               : 953869 MB
         Write Cache                        : Enabled (write-back)
         FRU                                : None
         S.M.A.R.T.                         : No
         S.M.A.R.T. warnings                : 0
         Power State                        : Full rpm
         Supported Power States             : Full rpm,Powered off
         SSD                                : No
         MaxCache Capable                   : No
         MaxCache Assigned                  : No
      Device #12
         Device is a Hard drive
         State                              : Failed
         Supported                          : Yes
         Reported Channel,Device(T:L)       : 0,19(19:0)
         Vendor                             : *MISSING*
         Model                              : 
         Firmware                           : 
         Size                               : 0 MB
         Write Cache                        : Unknown
         FRU                                : None
         S.M.A.R.T.                         : No
         S.M.A.R.T. warnings                : 0
         SSD                                : No
         MaxCache Capable                   : No
         MaxCache Assigned                  : No

このSlot:11 のDevice#12にランプを付けたい場合は

# arcconf identify 1 device 0 19
Controllers found: 1
The specified device is blinking.
Press any key to stop the blinking.

エンターを押すと点灯を終了する。
01_linux/99_その他/60_adaptech_raidのledランプを付ける.txt · 最終更新: 2020/10/03 07:08 by matsui