 <​code>​ <​code>​
 # hpssacli ctrl slot=0 modify cacheratio=10/​90 # hpssacli ctrl slot=0 modify cacheratio=10/​90
 +</​code>​
 +
 +
 +====== hpssacli hpcucli ssacli ======
 +
 +<​code>​
 +hpssacli
 +Posted on December 6, 2018 by Alwin
 +Show configuration:​
 +/​opt/​hp/​hpssacli/​bin/​hpssacli ctrl all show config
 +
 +Controller status
 +/​opt/​hp/​hpssacli/​bin/​hpssacli ctrl all show status
 +
 +Show detailed controller information for all controllers
 +/​opt/​hp/​hpssacli/​bin/​hpssacli ctrl all show detail
 +
 +Show detailed controller information for controller in slot 0
 +/​opt/​hp/​hpssacli/​bin/​hpssacli ctrl slot=0 show detail
 +
 +Rescan for New Devices
 +/​opt/​hp/​hpssacli/​bin/​hpssacli rescan
 +
 +Physical disk status
 +/​opt/​hp/​hpssacli/​bin/​hpssacli ctrl slot=0 pd all show status
 +
 +Show detailed physical disk information
 +/​opt/​hp/​hpssacli/​bin/​hpssacli ctrl slot=0 pd all show detail
 +
 +Logical disk status
 +/​opt/​hp/​hpssacli/​bin/​hpssacli ctrl slot=0 ld all show status
 +
 +View Detailed Logical Drive Status
 +/​opt/​hp/​hpssacli/​bin/​hpssacli ctrl slot=0 ld 2 show
 +
 +Create New RAID 0 Logical Drive
 +/​opt/​hp/​hpssacli/​bin/​hpssacli ctrl slot=0 create type=ld drives=1I:​1:​2 raid=0
 +
 +Create New RAID 1 Logical Drive
 +/​opt/​hp/​hpssacli/​bin/​hpssacli ctrl slot=0 create type=ld drives=1I:​1:​1,​1I:​1:​2 raid=1
 +
 +Create New RAID 5 Logical Drive
 +/​opt/​hp/​hpssacli/​bin/​hpssacli ctrl slot=0 create type=ld drives=1I:​1:​1,​1I:​1:​2,​2I:​1:​6,​2I:​1:​7,​2I:​1:​8 raid=5
 +
 +Delete Logical Drive
 +/​opt/​hp/​hpssacli/​bin/​hpssacli ctrl slot=0 ld 2 delete
 +
 +Add New Physical Drive to Logical Volume
 +/​opt/​hp/​hpssacli/​bin/​hpssacli ctrl slot=0 ld 2 add drives=2I:​1:​6,​2I:​1:​7
 +
 +Add Spare Disks
 +/​opt/​hp/​hpssacli/​bin/​hpssacli ctrl slot=0 array all add spares=2I:​1:​6,​2I:​1:​7
 +
 +Enable Drive Write Cache
 +/​opt/​hp/​hpssacli/​bin/​hpssacli ctrl slot=0 modify dwc=enable
 +
 +Disable Drive Write Cache
 +/​opt/​hp/​hpssacli/​bin/​hpssacli ctrl slot=0 modify dwc=disable
 +
 +Erase Physical Drive
 +/​opt/​hp/​hpssacli/​bin/​hpssacli ctrl slot=0 pd 2I:1:6 modify erase
 +
 +Turn on Blink Physical Disk LED
 +/​opt/​hp/​hpssacli/​bin/​hpssacli ctrl slot=0 ld 2 modify led=on
 +
 +Turn off Blink Physical Disk LED
 +/​opt/​hp/​hpssacli/​bin/​hpssacli ctrl slot=0 ld 2 modify led=off
 +
 +Modify smart array cache read and write ratio (cacheratio=readratio/​writeratio)
 +/​opt/​hp/​hpssacli/​bin/​hpssacli ctrl slot=0 modify cacheratio=100/​0
 +
 +Enable smart array write cache when no battery is present (No-Battery Write Cache option)
 +/​opt/​hp/​hpssacli/​bin/​hpssacli ctrl slot=0 modify nbwc=enable
 +
 +Disable smart array cache for certain Logical Volume
 +/​opt/​hp/​hpssacli/​bin/​hpssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=disable
 +
 +Enable smart array cache for certain Logical Volume
 +/​opt/​hp/​hpssacli/​bin/​hpssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=enable
 +
 +Enable SSD Smart Path
 +/​opt/​hp/​hpssacli/​bin/​hpssacli ctrl slot=0 array a modify ssdsmartpath=enable
 +
 +Disable SSD Smart Path
 +/​opt/​hp/​hpssacli/​bin/​hpssacli ctrl slot=0 array a modify ssdsmartpath=disable